Insulating Glass Systems K Series is produced with Şişecam Solar Low-E Glass with high quality heat and solar control coating. By providing maximum thermal insulation and solar control, it reduces your fuel costs in winter and air conditioning costs in summer.
Compared to ordinary double glazing, it reduces fuel costs in winter by reducing heat losses by 50% and reduces air conditioning costs in summer by reducing solar heat penetration by 40% and saves energy.
It provides heat and solar control without compromising transparency and natural daylight.
It prevents window fronts from being cold in winter and hot in summer and delays fogging compared to ordinary double glazing.
Compared to ordinary double glazing, the expenditure you will make for Insulating Glass K returns in 1-2 years with the savings you will save on fuel and air conditioning costs.
Safety + Security
The insulating glass unit, which is produced using Şişecam Solar Low-E Glass, which provides heat and solar control, and Şişecam Laminated Glass, which provides safety and security, prevents injuries that may occur by preventing the glass from scattering in case of breakage, in addition to the savings it provides to fuel and air conditioning costs.
Safety + Security + Noise Control
Produced by using Şişecam Solar Low-E Glass, which provides heat and solar control, and Şişecam Acoustic Laminated Glass, which provides noise control, the Insulating Glass unit reduces noise transmissions by providing sound insulation in addition to the savings it provides in fuel and air conditioning costs, and has the safety and security feature of Şişecam Laminated Glass.
Safety
Produced by using Şişecam Solar Low-E Glass, which provides heat and solar control, and Şişecam Acoustic Laminated Glass, which provides noise control, the Insulating Glass unit reduces noise transmissions by providing sound insulation in addition to the savings it provides in fuel and air conditioning costs, and has the safety and security feature of Şişecam Laminated Glass.
Maximum Insulation
It is a triple insulating glass unit that provides maximum thermal insulation and solar control. It provides 4 times heat insulation compared to ordinary double glazing.
By choosing your insulating glass according to the climatic conditions of your region, you will provide the most accurate and efficient insulation.
In new or renovated residential and commercial buildings, you will get additional benefits when you use it together with Safety and Security glass, Noise Control glass and Solar Control glass according to your needs.
Insulating Glass Systems is an insulating glass unit consisting of two or more glass plates produced and/or sold by Şişecam Flat Glass and brought together under factory conditions to accommodate dry air or gases suitable for ambient pressure.
Performans Tablosu
Up= 2.4 W/m²K value (glass + joinery, heat transmission coefficient of windows) recommended for new buildings in TS 825 Thermal Insulation Rules Standard can be achieved with Isıcam S and Isıcam K.
Solar Low-E coating is on the 2nd surface in Insulating Glass K units.
In Isıcam K combinations to be made with colored glass, the rated/performance values given according to the combinations of products with colorless glass may vary.
National / International Standards to which Insulating Glass Complies
TS EN 1279 - Glass - Used in Buildings - Glass Insulation Units Standard
National / International Standards for Raw Materials Used
Insulating Glass Quality
Optical and appearance quality of insulating glass is defined in TS EN 1279/1. Accordingly, the optical and appearance quality given in the relevant standards of the glasses that make up Insulating Glass is valid.
As the appearance and quality of the single plates are such that they do not exceed the maximum permissible defect limit for the insulating glass unit, no additional requirements are necessary in this respect. However, a higher level of acceptance may be included in the quality agreement between the customer and the manufacturer of the insulating glass unit
Detailed information on the optical and appearance quality of insulating glass due to its natural structure and / or physical properties is given in TS EN 1279-1 Annex F.
Acceptance levels in TS EN 1279-1 are valid as point defects in insulating glass.
Produced and/or sold by Şişecam Flat Glass Solar Low-E, Low-E, above the line reflective solar control coated glass produced by the coating of insulating glass units, TS EN 1096 Coated glass standard tolerances apply.
Optical and appearance quality of insulating glass is defined in TS EN 1279/1. Accordingly, the optical and appearance quality given in the relevant standards of the glasses that make up Insulating Glass is valid.
As the appearance and quality of the single plates are such that they do not exceed the maximum permissible defect limit for the insulating glass unit, no additional requirements are necessary in this respect. However, a higher level of acceptance may be included in the quality agreement between the customer and the manufacturer of the insulating glass unit.
Detailed information on the optical and appearance quality of insulating glass due to its natural structure and / or physical properties is given in TS EN 1279-1 Annex F.
The acceptance levels in TS EN 1279-1 are valid as linear defects in insulating glass.
As it is known, the separating material (lucite powder, paper, etc.) placed between the plate glasses prevents the glasses from rubbing against each other and protects the glass surface against humidity and temperature changes. The powder or paper placed between the glasses is of a composition that will not damage the chemical structure of the glass in terms of its properties, and no powder or paper is used. The grain size is as important as the chemical structure of the powder used. For this reason, the paper and powder to be placed between the glasses are specially selected and controlled.
Corrosion failure occurs as a result of the deterioration of the chemical structure of the glass due to the condensation of moisture in the air or wetting in the point-worn areas formed by the friction of the glass plates. The corrosion defect appears as white spots on the glass in the advanced stage. In the initial stage, it may not be visible to the naked eye. For this reason, it should be checked whether the corrosion has started or not, by vaporizing the glasses from time to time from a close distance. Corrosion failure is not allowed in the insulating glass unit. For this reason, care must be taken in the storage and transportation of glass packages. Especially in the winter months, when glass packages are taken into operation, the package should not be opened and processed until the package temperature reaches the ambient temperature.
The glass plate surfaces facing the gap must be free of dust, dirt, putty smudges, fingerprints, etc.
PROCESSING AND APPLICATION
Insulating Glass Edge Features
The edges of the glass should be cut straight and there should be no nicks or chips that could cause the glass to break. To reduce the risk of breakage and cracking due to thermal stress, etc., it is recommended that laminated glass be deburred (tape grinding) or polished.
It should be drawn smoothly and without interruption, especially in the corners. Butyl weight should be 2.5 g/m on both sides of the profile. Butyl width should be at least 3 mm in the pressed unit.
In gas-filled units, the butyl weight should be at least 3.0 g/m on both sides of the profile and the width should be at least 4 mm in the pressed unit.
It should not escape from the profile edge into the unit. Thiokol/polyurethane gap is at least 3 mm and silicone gap is at least 6 mm. For insulating glass used in structural glazing, the design criteria specified in the project are applied.
Gaz dolgulu ünitelerde thiokol ya da poliüretan boşluğu en az 4 mm olmalıdır.
Profilde kabul edilebilir sehim (doğrultudan sapma), kenar uzunluğu 3.500 mm’den küçük camda en fazla 4,0 mm, daha büyük camda en fazla 6,0 mm olabilir.
It is recommended to use a bent profile for gas filled units. If a cut profile is used, the top of the clip (the surface that will be in contact with the outer insulation paste) should be covered with some butyl at the corners where the clips enter the profile.
When producing insulating glass with soft coated glasses such as Low-E, Solar Low-E, the edge of the coated glasses should be edged with a 10 mm wide edge stripping process if production will be made with polyurethane or polysulfide, and 13 mm wide edge stripping process if production will be made with silicone.
Pressure Compensation Application in Insulating Glass
Insulating glass units may undergo deformation due to differences between the atmospheric pressure at the production site and the atmospheric pressure at the assembly site and on the route during transportation. Pressure equalization is performed to prevent this.
Conditions requiring pressure equalization
Pressure equalization is applied as follows.
Insulating Glass Stock Instruction
The following rules should be observed when stocking insulating glass units.
THICKNESS AND DIMENSIONS
Standard Thickness and Dimensions
Isıcam’ın boyut toleransları (EN 1279’a göre)
Insulating glass unit thickness tolerances
Tolerance of misalignment between insulating glass unit plates
We operate in our 10,500 square meter factory located in Antalya Organized Industrial Zone.
Our production includes insulating glass production, tempered glass production, laminated glass production, painted glass production and mirror types.
With 2 insulating glass production lines, we have an average daily production capacity of 1200 square meters of glass.