Şişecam Colored Float Glass, mainly in non-residential buildings with curtain walls, in all buildings requiring solar control; It is used in windows, parapets, wall fronts, roof skylights and glass balconies.
It is also used in decoration as table, coffee table, shelf, door, shower cabin and partition glass.
Performans Tablosu


"Daylight" and "Solar Energy" values were calculated in the "TNO Science and Industry" - WIS 3.01 package program using spectral data measured in the laboratory in accordance with EN 410 standard.
The U value, which is the coefficient of thermal conductivity, was calculated with the WIS 3.01 program in accordance with EN 673 standard. The emissivity values used in the U value calculation were measured in the laboratory in accordance with EN 673 (Annex A) and EN 12898.
The risk of thermal breakage may arise due to factors such as exposure to partial solar radiation along the surfaces of the glass, temperature differences between day and night, heat absorption coefficients of the glass or joinery types. Depending on these factors, it may be necessary to use tempered or partially tempered glass. This document does not contain any calculations for thermal breakage risks. Please contact Şişecam Flat Glass for your questions on this subject.
In units built with tinted solar control glass, it is recommended to use tinted glass as exterior glass.
This document is for informational purposes only and the information contained in it can be changed by Şişecam Flat Glass without any warning.
There may be differences between the values given in this document and the actual values depending on the conditions at the place of use. Şişecam Flat Glass cannot be held responsible for these differences in any way.
Daylight Transmittance: It is the percentage of light incident on the glass that passes through the glass.
Daylight Reflectance (exterior): The percentage of light incident on the glass that is reflected back by the glass.
Solar Total Transmittance: It is the percentage of the total solar energy incident on the glass that penetrates. A lower solar total transmittance value means better solar control.
Shading Coefficient: Total transmittance of solar energy compared to 3 mm colorless glass. Lower shading coefficient means better solar control.
Heat Transmission Coefficient: It is a measure of thermal insulation in glass. A lower U-value means better thermal insulation, less heating costs and more winter comfort.
Quality
Şişecam Colored Float Glass series, "TS 10288 EN 572-2 Glass-Used in Buildings-Basic Soda Lime Silicate Glass Products Section: 2 Float Glass" standard is produced in accordance with.